联想笔记本系列清除BIOS密码四种方法
[10-10 20:42:03] 来源:http://www.88dzw.com 电路学习 阅读:8604次
文章摘要:ON OFF OFF ON OFF 1.525ON OFF OFF ON ON 1.550ON OFF ON OFF OFF 1.575ON OFF ON OFF ON 1.600ON OFF ON ON OFF 1.625ON OFF ON ON ON 1.650ON ON OFF OFF OFF 1.675ON ON OFF OFF ON 1.700ON ON OFF ON OFF 1.725ON ON OFF ON ON 1.750ON ON ON OFF OFF 1.775ON ON ON OFF ON 1.800ON ON ON ON OFF 1.825ON ON ON ON ON
联想笔记本系列清除BIOS密码四种方法,标签:学习园地,http://www.88dzw.comON OFF OFF ON OFF 1.525
ON OFF OFF ON ON 1.550
ON OFF ON OFF OFF 1.575
ON OFF ON OFF ON 1.600
ON OFF ON ON OFF 1.625
ON OFF ON ON ON 1.650
ON ON OFF OFF OFF 1.675
ON ON OFF OFF ON 1.700
ON ON OFF ON OFF 1.725
ON ON OFF ON ON 1.750
ON ON ON OFF OFF 1.775
ON ON ON OFF ON 1.800
ON ON ON ON OFF 1.825
ON ON ON ON ON 1.850
V21
CPU跳线
K6系列
This section provides an easy step in doing system upgrades for your notebook computer.
Jumper Settings
This section provides a jumper setting lists of configuring the notebook.
Keyboard Type Select
K/B Type Pos #1 POS #2
US KEYBOARD OFF OFF
RESERVE OFF ON
JP KEYBOARD ON OFF
UK KEYBOARD ON ON
Logo Select
Logo Pos #3
RESERVE OFF
RESERVE ON
Password Override ( CMOS / RTC Data ) Jumper Setting
Password Override Pos#4
RTC Battery Normal OFF
Clear (RTC) DATA ON
i Before doing password override, take off AC adapter and battery first.
Main Board ID Select
Main Board ID Pos #5
RESERVE OFF
RESERVE ON
CD-ROM Master / Slave Select
CD-ROM Pos #6
Master ON
Slave OFF
i Pos # 8 is N/A Pin for reserve
S60
CHKPW
DISABLE ENABLE
SW1-3 ON OFF
V71:
1:MODEM卡下面两焊点
K70:
Jumper Settings
This section provides a jumper setting lists of configuring the notebook.
Figure 2-5 Switch 5 Jumper Setting
Keyboard Type Select ( SW5 )
K/B Type Pos #1 POS #2
US KEYBOARD OFF OFF
RESERVE OFF ON
JP KEYBOARD ON OFF
UK KEYBOARD ON ON
Logo Select ( SW5 )
Logo Pos #3
RESERVE OFF
RESERVE ON
69系列
Jumper Settings
This section provides a jumper setting lists of configuring the notebook. The jumper switches are near the memory socket. To access the jumper switches, you may refer to section 2.3.3 for procedures on how to access memory socket.
For CPU with SpeedStep (Geyserville) technology
Pos#1 Pos#2 Pos#3 Pos#4 Pos#5 Pos#6
PIII 600 / 500MHz
SW4 On On On On Off On
SW5 Off On Off Off NC NC
PIII 650 / 500MHz
SW4 On On On On Off On
SW5 Off On Off Off NC NC
For CPU without SpeedStep (Geyserville) technology
Pos#1 Pos#2 Pos#3 Pos#4 Pos#5 Pos#6
PIII 450MHz
SW4 On Off Off Off Off Off
SW5 On On On Off NC NC
PIII 500MHz
SW4 On Off Off Off Off Off
SW5 On On On Off NC NC
Celeron 450MHz
SW4 On Off Off Off Off Off
SW5 On On On Off NC NC
Celeron 500MHz
SW4 On Off Off Off Off Off
SW5 On On On Off NC NC
CPU Core Voltage Jumper Setting
Low VoltageHigh Voltage SW5-#1SW4-#2 SW5-#2SW4-#3 SW5-#3SW4-#4 SW5-#4SW4-#5 SW4-#1SW4-#6
0.00v Off Off Off Off On
1.30v On Off Off Off On
1.35v Off On Off Off On
1.40v On On Off Off On
1.45v Off Off On Off On
1.50v On Off On Off On
1.55v Off On On Off On
1.60v On On On Off On
1.65v Off Off Off On On
1.70v On Off Off On On
1.75v Off On Off On On
1.80v On On Off On On
- 上一篇:移动硬盘常见故障分析与解决方法
《联想笔记本系列清除BIOS密码四种方法》相关文章
- › 删除联想笔记本的LEOS方法
- › 联想笔记本换内存后为何频繁重启
- › 联想笔记本触控板问题
- › 联想笔记本黑屏
- › 联想笔记本电池使用时间过短
- › 联想笔记本在运行某些程序过程中报错,死机
- 在百度中搜索相关文章:联想笔记本系列清除BIOS密码四种方法
- 在谷歌中搜索相关文章:联想笔记本系列清除BIOS密码四种方法
- 在soso中搜索相关文章:联想笔记本系列清除BIOS密码四种方法
- 在搜狗中搜索相关文章:联想笔记本系列清除BIOS密码四种方法
编辑推荐
- · 空调除湿功能的原理
- · 传声器的主要技术指标
- · 超低压差稳压电路
- · EMS
- · 直流电机的均压线、作用,怎样设置均压线
- · 杜比定向逻辑环绕声系统
- · 空调除湿功能的原理
- · 传声器的主要技术指标
- · 超低压差稳压电路
- · EMS
- · 直流电机的均压线、作用,怎样设置均压线
- · 杜比定向逻辑环绕声系统
- · 给移动硬盘添加“动力”
- · VOD卡拉OK歌厅系统简介及特点
- · 单相电度表是如何接线的
- · 三招小秘笈测验你的音箱 试音小诀窍